Panasonic CS-XZ7SKEW Service Manual page 80

Hide thumbs Also See for CS-XZ7SKEW:
Table of Contents

Advertisement

Remote Control Receiving Sound
Normal Operation
o
nanoe Operation
o
Stop
o
nanoe individual Operation
o
Power failure
During nanoe individual operation, if power failure occurs, after power resumes, nanoe individual operation
o
resumes immediately.
During combination operation, if power failure occurs, after power resumes, combination operation resume
o
immediately.
nanoe check mode
To enable nanoe check mode, during nanoe operation ON:
o
During nanoe check mode, H67 is judged when disconnection detected. Timer LED blinks.
o
nanoe Abnormal Detection
Disconnection Abnormality
o
Abnormal detection condition
Start from 1 sec after nanoe power ON, 6 secs has passed and in this 6 secs period, abnormal signal
is detected continuously for 5.9 secs.
Action after abnormal detection condition fulfilled
Disconnection counters +1, nanoe power OFF for 5 minutes and then restart. However, according to
action mode and disconnection counter, below will be implemented:
During nanoe Check Mode: Disconnection abnormality will judged when disconnection counter
o
≥ 1. Abnormal code: H67 will memorized in EEPROM, Timer LED blinking and nanoe LED Off.
Other Than Above: Disconnection abnormality will judged when disconnection counter ≥ 3.
o
Abnormal code: H67 will memorized in EEPROM and nanoe LED OFF, Timer LED not blinking.
Disconnection counters clear condition >
Disconnection counter will be cleared when operation stop. (Not nanoe Check Mode)
 nanoe Operation
 Normal Operation
 nanoe individual Operation
 Stop
Normal display mode
SW (t ≥ 0 secs)
Press
SW pressed continuously for t ≥ 5 secs to enter service zone
When
and press
SW's to choose function 57
Transmit
"NANOE CHECK" code
: Beep
: Beep
: Beep
: Long Beep
80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents