12.2.4.1
Wire Stripping Connecting and Requirement
Wire stripping
No loose strand
when inserted
Indoor/outdoor
connection
terminal board
5 mm or more
(gap between wires)
Conductor
Conductor over
fully inserted
inserted
ACCEPT
PROHIBITED
12.2.4.2
Cutting and Flaring the Piping
1
Please cut using pipe cutter and then remove the burrs.
2
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
down to avoid the metal powder entering the pipe.
3
Please make flare after inserting the flare nut onto the copper pipes.
Pipe
Reamer
Point down
1. To cut
2. To remove burrs
WARNING
Do not joint wires
Conductor not
fully inserted
PROHIBITED
Handle
Bar
Yoke
Core
Red arrow mark
Clamp handle
3. To fl are
RISK OF FIRE
JOINING OF
WIRES MAY
CAUSE
OVERHEATING
AND FIRE.
OR
OR
0 – 0.5 mm
Bar
Copper pipe
47
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
wiring rules.
Improper fl aring
Inclined Surface
Cracked Uneven
damaged
thickness
When properly fl ared, the internal surface of the
fl are will evenly shine and be of even thickness.
Since the fl are part comes into contact with the
connections, carefully check the fl are fi nish.