13. Auto White Balance 5800K Standard Data Input 2

RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
Subject
Filter
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 5800K Standard Data Input 2" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
4
F
A0
5
F
A1
6
F
A2
7
F
A3
8
6
B6
9
6
B6
10
B
70
11
B
70
12
6
37
13
6
01
14
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 90 to 97and A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
1
6
37
2
6
01
3
B
70
4
6
B6
5
6
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter C14 for color temperature
correction
F
90 to 97, A0 to A3
Procedure
Place the C14 filter on the
lens.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame
setting". (Refer to page 5-15)
2A
Press PAUSE button.
48
Press PAUSE button.
61
Press PAUSE button.
B0
Press PAUSE button.
Note down the data.
03
Note down the data.
10
0A
A5
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Procedure
00
00
Press PAUSE button.
Set data noted down at step
10, and press PAUSE button.
Set data noted down at step
8, and press PAUSE button.
Release the data setting
performed at step 2.
(Refer to page 5-14)
Remove the C14 filter on the
lens.

14. Auto White Balance 5800K Standard Data Input 3

RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
Subject
Filter
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 5800K Standard Data Input 3" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
4
F
A0
5
F
A1
6
F
A2
7
F
A3
8
6
B6
9
6
B6
10
B
70
11
B
70
12
6
37
13
6
01
14
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 98 to 9F and A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
1
6
37
2
6
01
3
B
70
4
6
B6
5
6
5-24
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter C14 for color temperature
correction
F
98 to 9F, A0 to A3
Procedure
Place the C14 filter on the
lens.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame
setting". (Refer to page 5-15)
2A
Press PAUSE button.
48
Press PAUSE button.
61
Press PAUSE button.
B0
Press PAUSE button.
Note down the data.
03
Note down the data.
10
0C
A5
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Procedure
00
00
Press PAUSE button.
Set data noted down at step
10, and press PAUSE button.
Set data noted down at step 8,
and press PAUSE button.
Release the data setting
performed at step 2.
(Refer to page 5-14)
Remove the C14 filter on the
lens.