Light Value Adjustment; Mixed Color Cancel Adjustment - Sony Cybershot DSC-P9 Service Manual

Digital still camera
Hide thumbs Also See for Cybershot DSC-P9:
Table of Contents

Advertisement

6. Light Value Adjustment

Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 2F to 50
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Adjusting method:
Order Page Address Data
1
2
3
6
01
0D
4
6
02
5
0
03
06
6
1
7
F
65
Note 3: The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
0
03
00
3
RadarW
RadarW
RadarW
RadarW
RadarW
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame
setting".
(Refer to page 5-15)
Press PAUSE button.
(Note 4)
Check the data changes to
"01".
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
Check that the displayed data
satisfies the AE level 2
specified value.
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-14)

7. Mixed Color Cancel Adjustment

To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
1
2
3
7
22
4
7
22
5
6
01
6
6
01
7
6
02
Note 2: The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
7
22
3
5-19
DSC-P9
RadarW
RadarW
RadarW
CAMERA
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
F
6E and 6F
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame
setting".
(Refer to page 5-15)
Note down the data.
00
Press PAUSE button.
D7
Press PAUSE button.
Press PAUSE button.
D5
(Note 2)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
Set the data noted down at
step 3, and press PAUSE
button.
Release the data setting
performed at step 1.
(Refer to page 5-14)

Advertisement

Table of Contents
loading

Table of Contents