Auto White Balance 5800K Standard Data Input 1 - Sony Cybershot DSC-P9 Service Manual

Digital still camera
Hide thumbs Also See for Cybershot DSC-P9:
Table of Contents

Advertisement

12. Auto White Balance 5800K Standard Data Input 1

RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end and
TELE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
88 to 8F, A0 to A3, B1, B3
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 5800K Standard Data Input 1" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
4
F
A0
2A
5
F
A1
48
6
F
A2
61
7
F
A3
B0
8
6
B6
9
6
B6
03
10
7
5D
11
7
5D
00
12
7
9D
13
7
9D
80
14
6
37
07
15
6
01
11
16
6
38
17
6
01
C3
18
6
02
19
7
5D
20
7
9D
21
6
01
00
22
23
B
70
24
B
70
10
25
6
37
08
Procedure
Place the C14 filter on the
lens.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Perform "Picture Frame
setting". (WIDE end)
(Refer to page 5-15)
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Note down the data.
Note down the data.
Press PAUSE button.
Note down the data.
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Set data noted down at step
10, and press PAUSE button.
Set data noted down at step
12, and press PAUSE button.
Press PAUSE button.
Perform "Picture Frame
setting". (TELE end)
(Refer to page 5-15)
Note down the data.
Press PAUSE button.
Order Page Address Data
26
6
01
27
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 88 to 8F, A0 to A3, B1 and B3.
Processing after Completing Adjustment:
Order Page Address Data
1
6
37
2
6
01
3
B
70
4
6
B6
5
6
5-23
DSC-P9
Procedure
A5
Press PAUSE button. (Note 3)
Check the data changes to
"01".
Procedure
00
00
Press PAUSE button.
Set data noted down at step
23, and press PAUSE button.
Set data noted down at step
8, and press PAUSE button.
Release the data setting
performed at step 2.
(Refer to page 5-14)
Remove the C14 filter on the
lens.

Advertisement

Table of Contents
loading

Table of Contents