Table Of Contents - Carrier 42PQV...S Installation Manual

Table of Contents

Advertisement

42PQV...S/38VBH...S
1:1 inverter Heat pump system
For operation and maintenance instructions of this unit as well as installation
instructions, refer to owner's manuals.
Contents
General information .......................................................................................................................
Dimensions and weight .................................................................................................................
Connections ...................................................................................................................................
Minimum clearances and operating limits .....................................................................................
Material supplied and system charge ............................................................................................
Choosing the installation site .........................................................................................................
Warnings: avoid .............................................................................................................................
Installation for indoor unit ..............................................................................................................
Refrigerant connections ................................................................................................................
Check .............................................................................................................................................
Electrical connection for indoor unit ..............................................................................................
Electrical connection for outdoor unit ............................................................................................
Electrical connection .....................................................................................................................
Electrical data ................................................................................................................................
Pump down and refrigerant cycle ..................................................................................................
Operating test address selector and fault code .............................................................................
Maintenance and Troubleshooting ................................................................................................
ATTENTION INSTALLERS AND SERVICE TECHNICIANS!
AIR CONDITIONER WITH R-410A - QUICK REFERENCE GUIDE
• R-410A refrigerant operates at 50%-70% higher pressures than R-22. Be sure that servicing
equipment and replacement components are designed to operate with R-410A.
• R-410A refrigerant cylinders are pink.
• R-410A refrigerant cylinders have a dip tube which allows liquid to flow out with the cylinder in a vertical
position with the valve at the top.
• R-410A systems should be charged with liquid refrigerant. Use a commercial type metering device
in the manifold hose in order to vaporize the liquid refrigerant before it enters in the unit.
• R-410A, as other HFCs, is only compatible with oils selected by the compressor manufacturer.
• A vacuum pump is not enough to remove moisture from oil.
• Oils absorb moisture rapidly. Do not expose oil to atmosphere.
• Never open system to atmosphere while it is under vacuum.
• When the system must be opened for service, break vacuum with dry nitrogen.
• Do not vent R-410A into the atmosphere.
• Use only Carrier matching indoor units and outdoor units (Table I).
Table I
Indoor unit
42PQV009S
42PQV012S
Outdoor unit
38VBH009S
220-240V, 50/60Hz
38VBH012S
Power supply
Oil type
PVE
PVE
Page
2
3
3
4
5
6
7/8
9/10
11/13
14
15
16
17
17