9. 3D function test
9.1 Test equipment
(1) Pattern Generator MSHG-600 or MSPG-6100 (HDMI 1.4
support)
(2) Pattern: HDMI mode (model No. 872, pattern No. 83)
9.2 Test method
(1) Input 3D test signal as Fig.1.
(2) Press 'OK" key as a 3D input OSD is shown.
(3) Check pattern as Fig2 without 3D glasses. (3D mode
without 3D glasses)
<OK in 3D mode without 3D glasses>
10. IR Blaster Function Test
10.1. Test equipment
(1) IR Blaster Jig
(2) Test Mode : Power Only Mode
10.2 Test method
(1) Input IR Blaster Jig to IR Blaster Phone Jack
(2) Press MPX Key
(3) Checked LED Lighting of IR Blaster Jig.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Fig.2
11. USB S/W Download
(optional, Service only)
(1) Put the USB Stick to the USB socket
(2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is lower
than that of TV set, it didn't work. Otherwise USB data is
automatically detected.
(3) Show the message "Copying files from memory"
(5) Updating Completed, The TV will restart automatically
(6) If your TV is turned on, check your updated version and
Tool option.
* If downloading version is more high than your TV have, TV
can lost all channel data. In this case, you have to channel
recover. If all channel data is cleared, you didn't have a DTV/
ATV test on production line.
* After downloading, TOOL OPTION setting is needed again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push "OK" button.
(3) Punch in the number. (Each model has their number.)
(4) Updating is staring.
(5) Updating Completed, The TV will restart automatically
(6) If your TV is turned on, check your updated version and
Tool option.
* If downloading version is more high than your TV have, TV
can lost all channel data. In this case, you have to channel
recover. If all channel data is cleared, you didn't have a DTV/
ATV test on production line.
* After downloading, TOOL OPTION setting is needed again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push "OK" button.
(3) Punch in the number. (Each model has their number.)
- 17 -
LGE Internal Use Only