4.4.6. Reference (White Balance Adj. coordinate and
color temperature)
▪ Luminance: 204 Gray
▪ Standard color coordinate and temperature using CS-1000
(over 26 inch)
Coordinate
Mode
X
Cool
0.269
Medium
0.285
Warm
0.313
▪ Standard color coordinate and temperature using CA-210(CH
18)
Coordinate
Mode
X
Cool
0.269±0.002
Medium
0.285±0.002
Warm
0.313±0.002
(2) O/S Module(AUO, CMI, Sharp,IPS...)
Coordinate
Mode
X
Cool
0.271±0.002
Medium
0.287±0.002
Warm
0.315±0.002
▪ Standard color coordinate and temperature using
CA-210(CH-18) – by aging time
Cool
Aging time
GP4
X
(Min)
269
1
0-2
283
2
3-5
282
3
6-9
281
4
10-19
279
5
20-35
277
6
36-49
274
7
50-79
271
8
80-149
270
9
Over 150
269
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Temp
△uv
Y
0.273
13,000K
0.0000
0.293
9,300K
0.0000
0.329
6,500K
+0.0030
Temp
Y
0.273±0.002
13,000K
0.293±0.002
9,300K
0.329±0.002
6,500K
Temp
Y
0.276±0.002
13,000K
0.296±0.002
9,300K
0.332±0.002
6,500K
Medium
Warm
Y
X
Y
X
273
285
293
313
293
299
313
320
291
298
311
319
290
297
310
318
289
295
309
316
284
293
304
314
279
290
299
311
277
287
297
308
274
286
294
307
273
285
293
306
4.5. Option selection per country
4.5.1. Overview
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu.
(2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is done
using +, - KEY
4.6. Tool Option Inspection
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option.
Model
Tool 1
47G2-UG
32903
55G2-UG
32905
4.7. Local Dimming Inspection (Optional)
△uv
(1) Press 'TILT" key of the Adj. R/C and check moving
0.0000
patterns. The black bar patterns moves from top to bottom.
If a local dimming function does not work, a whole screen
0.0000
shows full white
0.0000
△uv
0.0000
0.0000
0.0000
4.8. Ship-out mode check (In-stop)
▪ After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
▪ After final inspection, Always turn on the Mechanical S/W.
Y
4.9. WIFI MAC ADDRESS CHECK
329
a. Using RS232
339
337
Transmission
336
335
b. check the menu on in-start
330
325
323
320
319
Note that there are Wi-Fi MAC and MAC address.
Wi-Fi MAC is used for wireless network and MAC address is used
for wired network
- 15 -
Tool 2
Tool 3
Tool 4
Tool 5
8258
30472 12332
18441
8258
30472 12332
18441
Command
Set ACK
[A][l][][Set ID][][20][Cr]
[O][K][x] or [N][G]
LGE Internal Use Only
Tool 6 Tool 7
1322
5771
1322
5771