Indoor Fan Motor Operation; Outdoor Fan Motor Operation For S9/12/18Nk); Outdoor Fan Motor Operation (For S24/28Nk) - Panasonic CS-S9NKV Service Manual

Table of Contents

Advertisement

11.2 Indoor Fan Motor Operation

11.2.1
Basic Rotation Speed
Manual Fan Speed
Fan motor's number of rotation is determined according to remote control setting.
o
Auto Fan Speed
According to room temperature and setting temperature, indoor fan speed is determined automatically.
o
The indoor fan will operate according to pattern below.
o
Fan Speed
a
Higher
Medium
Lower
Feedback control
Immediately after the fan motor is started, feedback control is performed once every second.
o
During fan motor on, if fan motor feedback ≥ 2550 rpm or <50 rpm continuously for 10 seconds, the fan
o
motor error counter increased; fan motor is then stopped and restarted. If the fan motor error counter
increased to 7, then H19 – fan motor error is detected. Operation stopped and could not be restarted.
11.3 Outdoor Fan Motor Operation (For S9/12/18NK)
Outdoor fan motor is operated with one fan speed only. Outdoor fan turns on when compressor starts to operate. But
outdoor fan will turns off 30 seconds after compressor stops to operate.
Compressor
Outdoor Fan

11.4 Outdoor Fan Motor Operation (For S24/28NK)

There is 2 speeds for outdoor fan motor. Outdoor fan speed can be changed to Hi or SHi according to outdoor
temperature. By default, the outdoor fan speed is set to Hi. For Cooling or Soft Dry operation, when outdoor
temperature reaches 38°C the outdoor fan speed is set to SHi, when outdoor temperature reduced to 37°C the fan
speed will set to Hi again. Outdoor fan will turns off 30 seconds after compressor stops to operate.
Compressor
Outdoor Fan
Remote control
Tab
Hi
b
c
d
ON
ON
Fan Speed
30 sec
ON
ON
Fan Speed
30 sec
Me+
Me
Me-
e
f
g
[1 pattern : 10s]
OFF
OFF
OFF
OFF
57
Lo
h
a
b
ON
ON
ON
ON

Hide quick links: