STACKING THE WASHER AND DRYER (if desired)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT
local electrical inspector's use.
IMPORTANT
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Service must be performed by a qualified
installer.
• Proper installation is the responsibility of the
installer.
• Disconnect power before installing. Failure to do
so could result in serious injury or death.
WARNING
Use two or more people to install dryer.
Failure to do so may result in back or other injury.
• Avoid Tipping and Rupture of Utility Services.
Dryer must be securely attached to the washer.
DO NOT place the washer on top of the dryer.
Failure to do so could result in personal injury/
death or property damage.
• Mobile Home or Manufactured Home Installation
– Stacking of a gas dryer is not permitted in a
mobile home or manufactured home.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0" both sides; 1" rear; 1" top.
Consideration must be given to provide adequate
clearance for installation and service.
GE APPLIANCES STACK KIT:
Order on-line at GEApplianceParts.com, 24 hours a day or by
phone at 800.626.2002 during normal business hours.
Installation Instructions
– Save these instructions for
– Observe all governing
- Excessive Weight Hazard
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18" (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
• The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYER section.
• Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0" either side
1" front
1" rear
1" top
• Consideration must be given to provide adequate
clearance for installation and service.
• Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches
(387 square cm) of open area. If the closet
contains both a washer and a dryer, doors must
contain a minimum of 120 square inches (774
square cm) of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN
THE REAR OF THE DRYER, THE CONFIGURATION OF
THE DUCTING MAY REQUIRE GREATER THAN 1" OF
REAR CLEARANCE.
Gas Dryers Only:
• No other fuel burning appliance shall be installed
in the same closet as a gas dryer.
• The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than ½ psi (3.5 kPa).
• A 1/8 inch NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
Part Number
Accessory
GEFLSTACK
Complete Stack Kit
14
- Explosion Hazard