Checking Battery Specific Gravity - Windsor QSC20 Operating Instructions Manual

Windsor saber compact walk behind scrubber
Table of Contents

Advertisement

CHECKING BATTERY SPECIFIC GRAVITY

Use a hydrometer to check the battery specific
gravity.
Battery Check
CHECKING GRAVITY
A. Hydrometer
B. Battery
NOTE: Do not take readings immediately after
adding distilled water, if the water and acid are not
thoroughly mixed, the reading may not be
accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80°F
(27°C), the reading must be temperature
corrected.
To find the corrected specific gravity reading
when the temperature of the battery electrolyte is
other than 80°F (27°): Add (+) to the specific
gravity reading 0.004 (4 points), for each 10°F
(6°C) above 80° (27°C).
Subtract (-) from the specific reading 0.004 (4
points), for each 10°F (6°C) below 80°F (27°C).
SABER (QSC) 980067 11/13/02
BATTERY CONDITION
@ 80° F (27°C)
1.265
1.225
1.190
1.155
1.120
MAINTENANCE
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
4-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qscx20Qsc20tQscx20t

Table of Contents