Sony HCD-DR3 Service Manual page 14

Hide thumbs Also See for HCD-DR3:
Table of Contents

Advertisement

CD SECTION
Note:
1.
CD Block is basically constructed to operate without
adjustment. Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10MΩ impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
5.
Adjust the focus bias adjustment when optical pick-up block is
replaced.
RF Level Check
CD DECODER
oscilloscope
board
TP01
RF
VC
Procedure :
1.
Connect oscilloscope to test point TP01 on CD DECODER
board.
2.
Turned Power switch on.
3.
Put disc (YEDS-18) in and playback.
4.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
Adjustment Location:
[CD DECODER BOARD] — Component side —
14
All manuals and user guides at all-guides.com
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
+0.3
level: 1.0
Vp-p
–0.2
TP01
(VC)