OPERATING THE REMOTE CONTROL

Remote Control only: Install a A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not
used for long periods of time.
IMPORTANT: This remote control & dc fan motor are designed to perform a one time self calibration test. This test
will begin once a new code has been set, and will last approximately six minutes.
Your DC brushless motor is equipped with a self learning frequency function remote control. Restore power to ceiling fan
and test the transmitter as below for proper operation:
A. 1, 2, 3, 4, 5 and 6 button:
These six buttons are used to set the fan speed as follows:
1 = minimum speed
2 = low speed
3 = medium low speed
4 = medium speed
5 = medium high speed
6 = high speed
B.
Reverse button:
This button is used to change the direction of the rotation of the blades; forward for warm weather or reverse for warm
weather.
C.
Button:
This button turns the power Off and On to the Fan.
D.
Button:
These buttons turn the light ON or OFF, this fan's light will not dim. The following instructions apply to ceiling fans that
feature a DOWN light (
button) only or ceiling fans that feature an UP light (
button) and a DOWN light (
button)
that are controlled independent of each other.
Press and release the button for the desired light to turn the light ON or OFF. Press and hold the button to set the desired
light brightness. The light will cycle between bright and dim settings as long as the button is pressed. The light key has
an automatic auto-resume feature that allows the light to remain at the same brightness as the last time it was turned
off.
Note: The auto learning function will only mandate within 60 seconds when turning the fan's AC power ON.
1. Select desired frequency from the back of transmitter.
2. Press the transmitter's "SET" button, and hold the "SET" button for over 5 seconds. Once the receiver has detected
the frequency, the fan will automatically begin to operate and start to rotate in the counter-clockwise direction and on
the highest RPM for 3 minutes. When counter-clockwise rotation has finished, the fan will automatically reverse to
clockwise direction again to the highest RPM for 3 minutes. Fan will shut off when the self calibration test has finished.
The total self calibration test will last about 6 minutes.
Note: During self calibration test, the remote will be non-function.
Note: The learning frequency function and self calibration test will continue to retain the last set frequency and
calibration set even when the AC power is shut off. If the frequency is changed the self calibration test will occur again.