Vent Tables - Bradford White PDV Series Service Manual

Residential & light duty commercial power direct vent models
Hide thumbs Also See for PDV Series:
Table of Contents

Advertisement

Condensing PDV Series

Vent Tables

Terminating
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Terminating
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Terminating
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Roof
2" Diameter (5.1 cm) Vent Connector Lengths
# of
Maximum Straight
Elbows
Length ft. (m)
1
2
3
4
0
1
2
3
4
3" Diameter (10.2 cm) Vent Connector Lengths
# of
Maximum Straight
Elbows
Length ft. (m)
1
2
3
4
5
0
1
2
3
4
4" Diameter (10.2 cm) Vent Connector Lengths
# of
Maximum Straight
Elbows
Length ft. (m)
1
2
3
4
5
0
1
2
3
4
Minimum Straight
Length ft. (m)
45 (13.7)
2 (.6)
40 (12.2)
2 (.6)
35 (10.7)
2 (.6)
30 (9.2)
2 (.6)
50 (15.2)
7 (2.1)
45 (13.7)
7 (2.1)
40 (12.2)
7 (2.1)
35 (10.7)
7 (2.1)
30 (9.2)
7 (2.1)
Minimum Straight
Length ft. (m)
115 (35.0)
10 (3.1)
110 (33.5)
10 (3.1)
105 (32.0)
10 (3.1)
100 (30.5)
10 (3.1)
95 (29.0)
10 (3.1)
120 (36.6)
15 (4.6)
115 (35.0)
15 (4.6)
110 (33.5)
15 (4.6)
105 (32.0)
15 (4.6)
100 (30.5)
15 (4.6)
Minimum Straight
Length ft. (m)
180 (54.9)
10 (3.1)
175 (53.3)
10 (3.1)
170 (51.8)
10 (3.1)
165 (50.3)
10 (3.1)
160 (48.8)
10 (3.1)
180 (54.9)
15 (4.6)
175 (53.3)
15 (4.6)
170 (51.8)
15 (4.6)
165 (50.3)
15 (4.6)
160 (48.8)
15 (4.6)
7
7

Advertisement

Table of Contents
loading

Table of Contents