Connection Plugs - DeWalt DXGNR 5700 Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

Operation
2
3
9
18
7000 - Canada (CSA listed)
16
12
17
6
5
15
11
14
4
13
Hour Meter (if equipped)
The Hour Meter tracks hours of operation for scheduled
maintenance.
The CHG OIL display will illuminate every 100 hours. The
message will flash one hour before and one hour after
each 100 hour interval, providing a two hour window to
perform service.
The SVC display will illuminate every 100 hours. The mes-
sage will flash one hour before and one hour after each
200 hour interval providing a two hour window to perform
service.
8
22
1
20
3
21
003606
7
19
000786
10
000788
8
When the hour meter is in flash alert mode, the mainte-
nance message will alternate with elapsed time in hours
and tenths. The hours will flash four times, then alternate
with the maintenance message four times until the meter
automatically resets.
100 hours - CHG OIL — Oil Change Interval (Every 100
hrs)
200 hours - SVC — Service Air Filter (Every 200 hrs)
The hour glass icon will flash when the
NOTICE:
engine is running. This signifies the
meter is recording hours of operation.
0000.0

Connection Plugs

120 VAC, 20 Amp, GFCI Duplex Receptacle
This is a 120 Volt outlet protected against overload by a
20 Amp push-to-reset circuit breaker. Use each socket to
power 120 Volt AC, single phase, 60 Hz electrical loads
requiring up to a combined 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-insulated, 3-
wire grounded cord sets rated for 125 Volts at 20 Amps
(or greater).
Keep extension cords as short as possible to prevent
voltage drop and possible overheating of wires.
Owner's Manual for Portable Generator
000205
000203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxgnr 7000

Table of Contents