Advertisement

Fresh air condition
Air
Model
Rated
Rated
Flow
Water
Cooling
Heating
Flow
Capacity
Capacity
39TF
m
3
/h
kW
kW
I/s
010
1000
13.9
13.2
0.66
015
1500
18.7
18.4
0.93
020
2000
27.0
27.5
1.29
025
2500
30.8
31.8
1.47
030
3000
39.9
40.9
1.90
040
4000
49.7
51.1
2.37
050
5000
64.5
64.0
3.07
060
6000
72.7
75.5
3.46
070
7000
84.1
87.1
4.00
080
8000
99.0
101.7
4.71
090
9000
111.0
113.8
5.29
105
10500
133.1
133.3
6.34
120
12000
149.4
155.1
7.12
135
13500
165.8
180.2
7.90
150
15000
184.2
200.2
8.77
NOTE:
1. Cooling capacity is based on the following:
a) Inlet and outlet water temperature: 7°C/12°C
2. Heating capacity is based on the following(with the same water flow rate as cooling mode):
a) Inlet and outlet water temperature: 60°C/50°C
3. The manufacturer reserves the rights to make changes to the above specifications without prior notice.
4. The water flow in the above table indicates the cold water supply flow. Because the hot water supply flow is smaller than cold water supply flow, cold water
supply flow is provided in the table for your reference to select the water pump.
AIR HANDLING UNIT
4Rows
Water
Chilled
Rated
Motor
Pressure
Water
Cooling
Power
Drop
Pipe
Capacity
kPa
kW
DN
kW
16.0
0.18
32
15.8
42.0
0.32
32
24.5
49.0
0.32
32
31.2
79.0
0.55
32
40.3
48.0
0.75
40
45.8
38.0
1.1
40
63.8
63.0
1.5
50
75.4
74.0
1.5
50
92.6
17.0
2.2
50
105.6
14.4
2.2
50
120.7
19.0
3.0
65
137.3
31.0
3.0
65
160.2
35.0
4.0
65
185.2
33.0
4.0
80
222.6
31.0
5.5
80
244.7
b) Air entering condition: 35°C DB/28°C WB
b) Air entering condition: 7°C DB
6Rows
Rated
Water
Water
Motor
Heating
Pressure
Flow
Power
Capacity
Drop
kW
I/s
kPa
kW
15.6
0.75
31.0
0.18
23.7
1.17
80.0
0.32
31.3
1.49
35.0
0.32
39.3
1.92
58.0
0.55
45.1
2.18
80.0
0.75
61.8
3.04
76.0
1.1
70.3
3.59
51.0
1.5
91.9
4.41
57.0
2.2
104.8
5.03
80.0
2.2
119.7
5.75
30.0
3.0
135.3
6.54
41.0
3.0
157.9
7.63
57.9
4.0
180.4
8.20
68.8
4.0
213.4
9.84
63.0
4.0
237.1
10.65
56.6
5.5
Sound
Condensate
Power
ESP
Chilled
Level
Water Pipe
Supply
Water
Pipe
DN
Pa
dB(A)
DN
32
80
53
25
32
80
53
25
32
80
55
25
40
120
56
25
40
160
59
25
50
200
60
25
50
200
62
25
380V
50Hz
50
200
63
25
65
240
64
25
65
240
64
25
65
280
66
25
80
280
67
25
80
280
68
25
80
320
68.5
32
80
320
69
32
CARRIER
Drive
Type
Direct
Drive
3N~
Belt
Drive
9