Smeg PM3912WLDDE Instructions Manual page 49

Table of Contents

Advertisement

90 cm models:
• 380-415 V 3N~ (default)
5 x 2.5 mm² five-core cable.
If the cable is replaced, the appliance can
also function in the following modes:
*use the jumper provided
• 380-415 V 2N~ / 220-240 V 3~
4 x 4 mm² four-core* cable.
• 220-240 V 1N~
3 x 6 mm² three-core* cable.
The values indicated above refer
to the cross-section of the internal
conductor.
Installation
The diagram below illustrates the power
supply terminal from below, with no cables
connected. Terminals 4 and 5 must be
connected at all times.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.