Functional Description
Notes
 •  A sshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenandClose
switch signals. Supplying power without entering the signals may damage the product.
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Preset, Swing, Group, Tour, Trace and A.Pan.
70
SPEED DOME CAMERA
User's Manual
Functional Description
25.2. Alarm Output
▶ Main Menu/Alarm Setting/Alarm Output
Setting 1,2 :
Main Menu
Enables selecting an Alarm Output method.
① Camera Setting
- 1, 2, 3, 4, and MD on the menu selection indicate the
② Sequence Setting
alarm input port and motion detection input. Up to 4
③ P/T Setting
alarm inputs can be set for each MD (Motion Detection)
④ OSD Setting
and TRK (Auto Track). 1 alarm output port can be used for
⑤ Alarm Setting
more than 2 alarm inputs along with ones for MD and
⑥ Initialize
TRK.
 Status
✽ The TRK function becomes activated only if the Zone mode
under Zone Settings under Auto Track 2 is set to Alarm.
Timer :
Alarm Setting
Enables selecting an Alarm Output method.
 Alarm Enable
OFF
- On : Retains an alarm output for a set duration from a
② Alarm Input
minimum of 1 second to a maximum of 60 hours
③ Alarm Output
upon the alarm occurrence.
④ Aux Output
- Momentary : Retains an alarm output only until the alarm
✽ The Alarm Output is equipped with a relay circuit. The
Alarm Output
operation of the alarm output port is as shown in the
 Setting1 □ 1 □ 2 □ 3 □ 4 □ MD □ TRK
diagram below.
 Setting2 □ 1 □ 2 □ 3 □ 4 □ MD □ TRK
 Timer
1 OFF
 Timer
1 OFF
Alarm Out OFF
Notes
 •   C onnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
 •  T hemaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera's
lifespan and damage it.
SPEED DOME CAMERA
is canceled.
NO
NO
COM
COM
NC
NC
Alarm Out ON