6
|
Application guidelines

6.4.4 DHW pump for instant hot water

6.4.5 DHW pump for disinfection

Installer reference guide
54
To heat up the DHW tank to the desired DHW tank temperature, you can use the
following energy sources:
-
Thermodynamic cycle of the heat pump
-
Electrical backup heater
For more information about optimizing the energy consumption for producing
domestic hot water, see "10 Configuration" [
Setup
a
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Recirculation connection
By connecting a DHW pump, instant hot water can be available at the tap.
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see
4
pump" [
 123].
For more information about connecting the recirculation connection, see
"8.2.5 To connect the recirculation
Configuration
For more information, see "10 Configuration" [
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
Setup
a
4
 134].
c
d
"9.3.5 To connect the domestic hot water
4
piping" [
 96].
4
b
c
d
e
b
 134].
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V