13
|
Maintenance and service
13.4 To drain the domestic hot water tank
Installer reference guide
242
DANGER: RISK OF BURNING/SCALDING
The water in the tank can be very hot.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Close the cold water supply.
Prerequisite: Open all the hot water tapping points to allow air to enter the
system.
1 Remove the top panel. See
2 Remove the user interface panel. See
3 Lower the switchbox. See
4
unit" [
71].
4 Remove the tube from the temperature and pressure relief valve that is
located on top of the tank.
5 Remove the temperature and pressure relief valve from the tank.
6 Use a drain hose and a pump to drain the tank via the access point.
1
7 Tightening torques for installation:
Tube connection
Temperature and pressure relief valve
"7.2.5 To open the indoor
"7.2.5 To open the indoor
"7.2.6 To lower the switch box on the indoor
2
Item
4
unit" [
69].
4
unit" [
69].
Tightening torque
30 N•m
40 N•m
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03