Trane TCONT900AC43UA Installer's Manual page 9

Hide thumbs Also See for TCONT900AC43UA:
Table of Contents

Advertisement

Installer Setup
Selection
Backup Heat source
0200
(Aux heat)
1st Stage
0220
Compressor Cycles
Per Hour (CPH)
2nd Stage
0230
Compressor Cycles
Per Hour (CPH)
1st Stage Heater
0240
Cycles Per Hour
(CPH)
2nd Stage Heater
0250
Cycles Per Hour
(CPH)
3rd Stage Heater
0260
Cycles Per Hour
(CPH)
Continuous Backlit
0280
Changeover
0300
Deadband
0310
Temperature
0320
Indication Scale
Daylight Savings
0330
Outdoor Temperature
0342
Sensor
Table 4. Installer Setup Menu
Factory
Number (ISU)
Setting
E
E
E
E
E
E
0
1
3
0
2
E
Choices
Option
Description
E, 0, 1
E - Auto-Discover
0 - Electric
1 - Fossil
E, 2-6
E - Auto-Discover
2 - 6 is available;
(3 is recommended)
E, 2-6
E - Auto-Discover
2 - 6 is available;
(3 is recommended)
E, 2-6
E - Auto-Discover
2 - 6 is available;
(3 is recommended)
E, 2-6
E - Auto-Discover
2 - 6 is available;
(5 is recommended)
E, 2-6
E - Auto-Discover
2 - 6 is available;
(5 is recommended)
0, 1
0 - Backlit not on
continuously. Comfort
Control backlight comes on
with a key press.
1 - Backlit is on
continuously. Comfort
Control backlight will come
on full brightness
with a key press and
display will dim 45
seconds after the last
keypress.
0, 1
0 - Manual Changeover
1 - Auto Changeover
3-9
3 - 3°F (2.0°C)
4 - 4°F (2.5°C)
5 - 5°F (3.0°C)
6 - 6°F (3.5°C)
7 - 7°F (4.0°C)
8 - 8°F (4.5°C)
9 - 9°F (5.0°C)
0, 1
0 - Temperature is
displayed in °F
1 - Temperature is
displayed in °C
0, 1, 2, 3 0 - Daylight savings is
disabled.
1 - Daylight savings is
enabled (US 1987)
2 - Daylight savings is
enabled (US 2007)
3 - Daylight savings is
enabled (Europe)
E, 0, 1
E - Auto-Discover
0 - None
1 - Installed Sensor
9
TCONT900AC43UA
Comments
HP only
Default value is 3 CPH if
nothing is discovered.
Default value is 3 CPH if
nothing is discovered.
Default value is 3 CPH if
nothing is discovered.
Default value is 5 CPH if
nothing is discovered.
Default value is 5 CPH if
nothing is discovered.
Shown only if automatic
changeover is selected. If
ISU 0380 is set to
Integrated Temperature and
Humidity Control (ITHC),
the deadband is restricted
to a range of 5 to 9.
Set to 0 for areas that do
not follow daylight savings.
All communicating outdoor
units are equipped with an
ambient temperature
sensor that will be auto-
discovered
Pub. No. 18-HD32D1-2
69-2079—05

Hide quick links:

Advertisement

Table of Contents
loading