Siemens SIMATIC NET RUGGEDCOM RSG2100PF Installation Manual page 36

Simatic net rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2100PF:
Table of Contents

Advertisement

Make sure all electrostatic energy is dissipated before installing or removing
components from the device. An electrostatic discharge (ESD) can cause serious
damage to the component once it is outside the chassis.
Only install GBIC optical ports that are compatible with the RUGGEDCOM
RSG2100PF.
1.
2.
3.
4.
5.
6.
RUGGEDCOM RSG2100PF
Installation Manual, 07/2021, C79000-G8976-1345-11
NOTICE
Make sure all potential electrostatic build-up has been properly discharged to
prevent electrostatic discharges (ESD). This can be accomplished by wearing an
ESD-preventive wrist strap connected to either the chassis ground connector or a
bare metal surface on the router/switch.
Remove the dust cover from the port opening in the module.
Remove the port from its packaging.
NOTICE
Mechanical hazard – risk of component damage
GBIC optical ports are designed to insert in only one orientation. Do not force
the port into the module.
Remove the dust plug from the socket and store for future use.
Squeeze the latches on either side of the port and insert the port into the socket.
GBIC Optical Port Module
1
Socket
2
Locking Latch
3
Figure 4.11
Installing a GBIC Optical Port
Release the latches and make sure the port is locked in place.
NOTICE
Only remove the dust plug when ready to connect a cable to the GBIC optical
port.
4.5.1 Installing a GBIC Optical Port
1
2
3
Communication Ports
27

Advertisement