Heat Mode Performance Data - Panasonic CS-BE35TKE Service Manual

Hide thumbs Also See for CS-BE35TKE:
Table of Contents

Advertisement

17.2 Heat Mode Performance Data

Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 220-230V
17.2.1
CS-BE25TKE CU-BE25TKE
Indoor (°C)
-15
DB
TC
24
1737
20
1740
16
1640
17.2.2
CS-BE35TKE CU-BE35TKE
Indoor (°C)
-15
DB
TC
24
1823
20
1826
16
1721
17.2.3
CS-BE50TKE CU-BE50TKE
Indoor (°C)
-15
DB
TC
24
3163
20
3168
16
2985
TC
- Total Cooling Capacity (W)
IP
- Input Power (W)
-7
IP
TC
IP
803
1928
865
759
2140
860
719
2185
823
-7
IP
TC
IP
928
2366
1057
878
2600
1050
831
2681
1005
-7
IP
TC
IP
1927
4127
2113
1824
4580
2100
1726
4676
2010
Outdoor WB (°C)
2
TC
IP
TC
2510
899
2912
2610
920
3150
2601
876
3329
Outdoor WB (°C)
2
TC
IP
TC
3099
1104
3550
3190
1130
3840
3211
1075
4059
Outdoor WB (°C)
2
TC
IP
TC
5222
2129
4992
5430
2180
5400
5410
2075
5707
108
7
12
IP
TC
781
3100
780
3225
779
3418
7
12
IP
TC
1042
3779
1040
3931
1039
4167
7
12
IP
TC
1592
5314
1590
5529
1588
5860
IP
777
777
776
IP
1036
1036
1034
IP
1584
1584
1581

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-be25tkeCs-be50tkeCu-be25tkeCu-be35tkeCu-be50tke

Table of Contents