8.4.16 Point check function
Press the LED
button of the remote controller three times, and then press
the
AIR DIRECTION
seconds. The air conditioner will enter into the information enquiry status. You can press the LED
or
AIR DIRECTION button to check the next or front item's information.
When the AC enter the "information enquiry" status, it will display the code name in 2 seconds, the
details are as follows.
Enquiry information
T1
T2
T3
T4
T2B
TP
TH
Targeted Frequency
Actual Frequency
Indoor fan speed
Outdoor fan speed
EXV opening angle
Compressor continuous running time
Causes of compressor stop.
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
When the AC enter into the information enquiry status, it will display the code value in the next 25s ,
button three times in ten seconds, the buzzer will keep ring for two
Displaying code
T1
T2
T3
T4
Tb
TP
TH
FT
Fr
IF
OF
LA
CT
ST
A0
A1
0
1
2
3
4
5
6
L
A
U
T
Meaning
Indoor room temp.
Indoor coil mid temp.
Outdoor coil temp.
Outdoor temp.
Indoor coil outlet temp.
Compressor discharge
temp
IPM modular temp.
Targeted Frequency
Actual Frequency
Indoor fan speed
Outdoor fan speed
EXV opening angle
Compressor continuous
running time
Causes of compressor
stop.
32