Fisher FSAIF-Pro-95AE2 Service Manual page 32

Split wall-mounted type
Table of Contents

Advertisement

(be lower than 30 ℃ ) every one hour, 2 hours
later the setting temperature stops rising and
the indoor fan is fixed at low speed.
When
heating,
the
decreases 1℃ (be higher than 17℃) every one
hour, 2 hours later the setting temperature
stops rising and indoor fan is fixed at low speed.
(Anti-cold wind function has the priority).
8.4.8.3 Operation time in sleep mode is 7 hours.
After 7 hours the AC quits this mode and turns
off.
8.4.8.4 Timer setting is available
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an
auto-restart module. In case of a sudden power
failure, the module memorizes the setting
conditions before the power failure. The unit will
resume the previous operation setting (not
including swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24℃ setting
temp.
If AC is off before power off and AC is required
to start up now, the compressor will have 1
minute delay when power on. Other conditions,
the compressor will have 3 minutes delay when
restarts.
8.4.10 Refrigerant Leakage Detection
With this new technology, the display area will
show "EC" when the outdoor unit detects
refrigerant leakage. This function is only
available in cooling mode.
8.4.11 Louver Position Memory Function
When starting the unit again after shutting down,
its louver will restore to the angle originally set
by the user, but the precondition is that the
angle must be within the allowable range, if it
exceeds, it will memorize the maximum angle
of the louver. During operation, if the power fails
setting
temperature
or the end user shuts down the unit in the turbo
mode, the louver will restore to the default
angle.
8.4.12 8℃ Heating(optional)
In heating operation, the preset temperature of
the air conditioner can be as lower as 8 ℃ ,
which keeps the room temperature steady at
8 ℃ and prevents household things freezing
when the house is unoccupied for a long time in
severe cold weather.
8.4.13 Self clean(optional)
For heat pump models which are provided with
this function, after running in cooling or drying
mode, if the user press "Self Clean" button on
remote controller, firstly, indoor unit runs in fan
only mode for a while, then low heat operation
and finally runs in fan only again. This function
can keep the inside of indoor unit dry and
prevent breeding of mold.
8.4.14 Follow me (optional)
1)
If the indoor PCB receives the signal which
results from pressing the FOLLOW ME button
on remote controller, the buzzer will emit a
sound and this indicates the follow me function
is initiated. But when the indoor PCB receives
signal which sent from remote controller every
3 minutes, the buzzer will not respond. When
the unit is running with follow me function, the
PCB will control the unit according to the
temperature from follow me signal, and the
temperature
collection
temperature sensor will be shielded, but the
error detective function of room temperature
sensor will be still valid.
2)
When the follow me function is available,
the PCB will control the unit according to the
room temperature from the remote controller
and the setting temperature.
3)
The PCB will take action to the mode
change information from remote controller
signal, but it will not affected by the setting
30
function
of
room

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents