Pin No.
Pin Name
43
GR-1
44 to 66 SEG-1 to SEG-23
67
LED STANDBY
68
VKK
69
VDD
70
XIN
71
VSS
72
XOUT
73
RESET
74
JOG A
75
JOG B
76
TEST
77
78
I2C DATA
79
I2C CLK
80
D-SW
54
I/O
O
Grid drive signal output to the fluorescent indicator tube (FL601)
O
Segment drive signal output to the fluorescent indicator tube (FL601)
O
LED drive signal output of the I/1 indicator (D601) "H": LED on
Power supply terminal (–35V) (for fluorescent indicator tube drive)
Power supply terminal (+5V)
I
System clock input terminal (12.5 MHz)
Ground terminal
O
System clock output terminal (12.5 MHz)
System reset signal input from the reset signal generator (IC801) "L": reset
I
For several hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
Jog dial pulse input from the rotary encoder (S763 JOG DIAL) (A phase input)
I
Jog dial pulse input from the rotary encoder (S763 JOG DIAL) (B phase input)
I
Connected to ground
Not used (open)
I/O
Communication data bus with the system controller (IC501)
Communication data reading clock signal input or transfer clock signal output with the system
I/O
controller (IC501)
I
CD door open/close detection switch (S742) input terminal "L": close, "H": open