Device Communication Io-Link - Siemens SITRANS L Series Operating Instructions Manual

Capacitance transmitters
Hide thumbs Also See for SITRANS L Series:
Table of Contents

Advertisement

Technical data and dimensions
10.2 Device communication IO-Link
10.2

Device communication IO-Link

In the following, the necessary device-specific details are shown. You can find further
information of IO-Link on
IO-Link specification: Revision 1.1
SIO mode: Yes
Speed: COM2 38.4 kBaud
Min. cycle time 4.0 ms
Length process data word: 32 Bit
IO-Link Data Storage: Yes
Block parameter adjustment: Yes
Byte
0
1
2
3
4
5
6
7, 8
9, 10,
11
Configuration
Bit
TransmitterX-value 0.1 % (frequency)
Formats
Out1
Out2
Temperature
X-value
Events
6202
6203
6204
6205
30
www.io-link.com
Parameter
-
MasterCycleTime
MinCycleTime
M-SequenceCapability
Revision ID
Input process data length
Output process data length
VendorID
DeviceID
31 (MSB) ...
16
[https://www.io-link.com].
HexCode
-
-
0x28
0x2B
0x11
0xC3
0x00
0x002A
0x0B1102
15
...
Temperature in °C, resolution
0.1 K
Value
Type
1 Bit
Boolean
1 Bit
Boolean
14 Bit
Integer
16 Bit
Integer
HexCode
Type
0x183A
FunctionCheck
0x183B
Maintenance
0x183C
OutOfSpec
0x183D
Failure
Note, value
-
-
4 ms
Frametypes, SIO-Mode, ISDU
IO-Link Revision 1.1
4 Byte Länge (SIO-Mode
verfügbar)
Not available
98
1024
2
1
0 (LSB)
Out2
Out1
SITRANS LCS050
Operating Instructions, 02/2021,
A5E50859888