Sony DNW-A100 Maintenance Manual page 98

Digital video hybrid recorder
Hide thumbs Also See for DNW-A100:
Table of Contents

Advertisement

3-1. Error Message
ERROR-11 TAPE TOP/END SENSOR TROUBLE
Description:
The tape top and tape end were detected simultaneously.
Detection conditions:
When the simultaneous detection of the tape end and tape top is continued for
more than seven seconds
Sub error message:
None
Possible cause:
. Tape top sensor or tape end sensor trouble
. Tape top or tape end detection circuit (MS-50 board) trouble
. Tape top/tape end input port (IC115 on SS-63 board) trouble
. Harness disconnection
Protection operation:
Stops the tape transport and enters the rest state during tape transport.
ERROR-12
TAPE TOP SENSOR TROUBLE
Description:
Malfunction of tape top sensor was detected.
Detection conditions:
When the tape top is detected continuously for more than seven seconds
Sub error message:
None
Possible cause:
. Tape top sensor trouble
. Tape top detection circuit (MS-50 board) trouble
. Tape top input port (IC115 on SS-63 board) trouble
. Harness disconnection
. The tape cannot move at the tape top due to troubles other than the tape sensor.
Protection operation:
In the FF mode, continues the operation until the tape end is detected. Stops the
tape transport and enters the rest state when the tape end is detected.
During tape transport in forward direction, the FF mode can be entered only
while the total tape quantity is observed.
Stops the tape transport and enters the rest state during tape transport except the
above.
3-10