Removing the burner

G
4x
C
D
E
B
Fig. 26
1. Switch OFF the power supply and the ON/OFF
switch at the control unit.
2. Close the gas shut-off valve and safeguard against
reopening.
3. Remove cables from fan motor
ignition and ionisation electrode
and earth tab
.
E
F
F
A
4. Undo gas supply pipe fitting
5. Undo four screws
, gas train
,
A
B
, ignition unit
C
D
Commissioning, inspection, maintenance
and remove the burner.
G
!
Please note
Prevent damage to the burner.
Never rest the burner on the burner gauze
assembly.
.