Generator Cabinet Specifications; General Input Power Specifications - GE Precision 500D Operator's Manual

Table of Contents

Advertisement

TABLE 11-3
GENERAL CABINET SPECIFICATIONS
Dimensions
Height:
Width:
Depth:
Weight:
NOTE:

3-2General Input Power Specifications

TABLE 11-4
MODEL DEPENDENT SPECIFICATIONS
PARAMETER
Input Voltage
Daily Voltage Variations
Line Impedance Specification
Line Impedance
HV cable type
Ground Wire
Inrush Current
Normal Frequency
Daily Frequency Variation
om 5184516-100 Rev. 5
Generator Cabinet
1600 mm
550 mm
450 mm
150kg
All specifications do not include measurement instumentation accuracy.
JEDI GENERATOR
380/400/415/440/460/480VAC three phase and Ground without neutral
+/– 10% (in this range, the generator shall operate without any derating in accuracy)
IEC Specification
The apparent line impedance guaranteed by the customer should be equal or less
than the values indicated below, according to the voltage value and the commercial
power of the generator.
Voltage range (V)
line impedance (Ohms)
3 (phase)
380
415
440
480
IB EEC: 22mm cable de Lyon (<=150pF/m)
USA: 22mm DSI (<=165pF/m)
EEC: 16mm Claymount (<=165pF/m)
HV cable connector=Federal standard
Same as power cable
600A
50/60Hz
+/–6%
65kW
80 kW
0.12
0.09
0.14
0.11
0.15
0.125
0.18
0.15
11-3