Panasonic CU-PC30JKF Service Manual page 34

Hide thumbs Also See for CU-PC30JKF:
Table of Contents

Advertisement

11.4.6. Precautions with Regard to Test Operation
• Use only insulation tool to switch on the microswitch on the
electric circuit board (do not use finger or metallic tool).
• Do not switch on power before all installation is completed.
• After power on, make sure the voltage is 90% ~ 110% of the
rated voltage.
• May use corresponding switches on the control panel of the
outdoor unit to initiate "Test run".
• Test run consists of
cooling and
mode unit does not have heating function).
• Press and hold SW1 more than 1 second. In DS1, under
different setting condition, outdoor unit will perform "cooling"
test run or "heating" test run.
DS1
1
2
3
4
u
u
ON
OFF
u
u
ON
ON
u
u
OFF
OFF
(Must first select "cooling" mode.)
When operation mode changes, the compressor stops operation momentary.
• Press SW1 again to cancel test run.
• If outdoor temperature is high during "heating" test run, or low during "cooling" test run, the protection system in the system will
be activated within several minutes.
heating modes (Single
Operation mode
"Cooling" test run
"Heating" test run
PUMP DOWN
34