8.2.

Outdoor Unit

8.2.1.
CU-PC30JKF
Resistance of Compressor Windings
MODEL
CONNECTION
C - R
C - S
Note: Resistance at 20qC of ambient temperature.
CU-PC30JKF
2JD514D5AA03
0.675 :
2.279 :
16
Resistance of Outdoor Fan Motor Windings
MODEL
CONNECTION
BLUE - YELLOW
YELLOW - RED
Note: Resistance at 20qC of ambient temperature.
CS-PC30JKF
CWA951658
73.6 :
94.8 :