NX-203
Item
Panel tuning mode
Low RSSI
1) Adj item: [Aw LRSSI]
at 118dBm
Adjust: [✳✳✳]
adjust *7
2) Adj item:
[AwL LRSSI]
[Analog
[AwL ' LRSSI]
Wide]
[AwC LRSSI]
[AwH' LRSSI]
[AwH LRSSI]
Adjust: [✳✳✳]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [Nv LRSSI]
Very
Adjust: [✳✳✳]
Narrow]
2) Adj item:
[NvL LRSSI]
[NvL ' LRSSI]
[NvC LRSSI]
[NvH' LRSSI]
[NvH LRSSI]
Adjust: [✳✳✳]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
*7: Because Low RSSI at –118dBm (NXDN Narrow) is adjusted by adjusting Low RSSI at –118dBm (Analog Narrow), it is not necessary to adjust
Low RSSI at –118dBm (NXDN Narrow).
7 . High RSSI
1) Adj item: [An HRSSI]
at –80dBm
Adjust: [✳✳✳]
adjust *8
2) Adj item:
[AnL HRSSI]
[Analog
[AnL ' HRSSI]
Narrow]
[AnC HRSSI]
[AnH' HRSSI]
[AnH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw HRSSI]
Wide]
Adjust: [✳✳✳]
2) Adj item:
[AwL HRSSI]
[AwL ' HRSSI]
[AwC HRSSI]
[AwH' HRSSI]
[AwH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
58
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Low RSSI
SSG
(Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [Low RSSI
(NXDN Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High RSSI
SSG
(Analog Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
Measurement
Test-
Unit
Terminal
Unit
Panel
ANT
Universal
connector
Panel
ANT
Universal
connector
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the ana-
log signal.
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks