Setting Guide
LGE Internal Use Only
200℃
11. DISASSEMBLE GUIDE
1. Remove the gasket & cameras from the PCB.
2. Set the BE/T 853A (Hot Plate) temperature to 200˚C
3. Pre-Heat the PCB for 1 minute on the Board support
guide as image
*Caution : C-Clip & Sensor Damage
4. Set the WHA3000P (Heat Gun) as below
TEMP
AIR
PREHEAT
400˚C
15L
OFF
- 266 -
Copyright © 2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes