2. Safety Protection
a. 2 thermostats are provided with the unit, and the heater circuit is shut down when their surface temperatures became over 
°
160
C.
b. The heater control circuit of IC300 has the built-in function that the software turns off the heater control automatically if the
heater is not turned ON every a fixed time.
c. When the temperature became over 250
(IC300-AC18pin becomes Low) will be executed.
The correspondence readings between temperature measured by thermistor and HEX readings
Temperature
 AD value
°
[C
]
0
252
1
251
2
251
3
251
4
251
5
251
6
251
7
250
8
250
9
250
10
250
11
249
12
249
13
249
14
249
15
248
16
248
17
248
18
248
19
247
20
247
21
247
22
246
23
246
24
246
25
245
26
245
27
245
28
244
29
244
°
C, the heater control circuit of IC300 is turned off forcedly and system reset
HEX reading
Temperature
°
[C
]
FC
84
FB
85
FB
86
FB
87
FB
88
FB
89
FB
90
FA
91
FA
92
FA
93
FA
94
F9
95
F9
96
F9
97
F9
98
F8
99
F8
100
F8
101
F8
102
F7
103
F7
104
F7
105
F6
106
F6
107
F6
108
F5
109
F5
110
F5
111
F4
112
F4
113
 AD value
HEX reading
202
CA
168
200
C8
169
199
C7
170
198
C6
171
197
C5
172
196
C4
173
195
C3
174
193
C1
175
192
C0
176
191
BF
177
190
BE
178
188
BC
179
187
BB
180
186
BA
181
184
B8
182
183
B7
183
182
B6
184
181
B5
185
179
B3
186
178
B2
187
177
B1
188
175
AF
189
174
AE
190
173
AD
191
171
AB
192
170
AA
193
168
A8
194
167
A7
195
166
A6
196
164
A4
197
Temperature
 AD value
HEX reading
°
[C
]
93
5D
92
5C
91
5B
90
5A
89
59
88
58
87
57
86
56
85
55
84
54
83
53
82
52
81
51
80
50
79
4F
78
4E
77
4D
76
4C
75
4B
74
4A
74
4A
73
49
72
48
71
47
70
46
69
45
68
44
68
44
67
43
66
42

Advertisement