Superior Fireplaces VRT3132WS Assembly, Installation And Operation Instructions page 13

Universal vent-free firebox
Table of Contents

Advertisement

Installation Instructions -
FBK-100 or FBK-200 Blower Kits and JBK Junction Box Kit
IMPORTANT
All electrical wiring must be performed by licensed Elec-
tricians. Electrical wiring must comply with the National
Electrical Code ANSI/ NFPA 70 - latest edition
Step 1. Follow the instructions below for the model you are installing:
Using a screwdriver remove the screw from the blower access panel
as shown in Figure 15. Slide the panel to the right until the flange
clears the opening. Remove the panel and set aside.
Step 2. Remove the rectangular knock-out (for J-Box) on the right side
of unit (see Figure 6 for location). Install the Junction Box and Electrical
outlet below the firebox floor into the rectangular opening on the right
side cabinet panel where you removed the knock-out (see Figures 17
and 18). The Junction Box / Electrical Kit is sold separately (see Page
16 for ordering information).
• Squeeze the J-Box flanges together to fit into the opening shown in
Figures 17 and 18.
• Wires will need to be passed through the hole shown in Figure 16.
• An approved strain relief bushing (not supplied with the kit), is required
to restrain the wires (see Figure 16).
Step 3. Loosely tie a knot in the power cord to take up slack (see Figure 19).
Step 4. Locate the tabs shown in Figure 20. Position the blower assembly
so that the tabs (located on the cabinet base) are seated in the notches of
the blower bracket. Bend the tabs over to secure the blower assembly (see
Figure 21).
Step 5. Plug power cord into the electrical outlet as illustrated in Figure 13.
Firebox
floor
Blower
Access
Panel
Remove screw, then lift out blower access panel.
Figure 15 -
Model VRT3136 Shown
Screw
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Cover Plate
Remove knock-out
(strain relief bush-
ing [not supplied]
presses into this
hole around romex
wires- see Step 8 on
Page 14).
Screw
Figure 16 -
Junction Box Kit
J-Box and Electrical Outlet
Firebox
floor
Install into side wall rectanular opening
Figure 17
Right Outside Cabinet Panel
J-Box Flanges
Wires
Figure 18
J-Box and
Receptacle
J-Box Flange
J-Box and
Electrical
Outlet
13