Operation/Diagnostics - Golden Technologies Compass TRO GP615 SS Owner's Manual

Center-wheel drive power chair
Table of Contents

Advertisement

Compass TRO Owner's Manual – Models: GP615 SS, GP615 CC

OPERATION/DIAGNOSTICS

For Compass TRO Units with the SHARK Controller
Flash codes indicate the nature of an abnormal condition directly from the SHARK
Information Gauge. Without the use of any servicing tools, the condition can be
simply diagnosed.
Flash
Code
1
User Fault
2
Battery Fault
3
Right Motor Fault
4
Left motor fault
5
Right park brake fault
6
Left park brake fault
7
SHARK Control Unit Fault
SHARK Power Module
8
Fault
SHARK Communications
9
Fault
10
Unknown Fault
The SHARK modules are not user serviceable. Do not attempt to repair Shark
modules.
Note that joystick OONAPU (Out Of Neutral At Power Up) is not a fault. Simply by
removing your hand from the joystick and allowing it to return to the neutral position,
the fault will immediately clear. If the condition persists after removing your hand, the
joystick may be damaged. Consult a Service agent.
Description
Recommended Action
Possible stall timeout or user error. Release
the joystick to neutral and try again.
Check the batteries and cabling. Try charging
the batteries. Batteries may require replacing.
Check the right motor, connections and
cabling.
Check the left motor, connections and
cabling.
Check the right park brake, connections and
cabling.
Check the left park brake, connections and
cabling.
Check the SHARK Communications Bus con-
nections and wiring. Replace the Control Unit
Check SHARK connections and wiring.
Replace the Power Module.
Check SHARK connections and wiring.
Replace the SHARK Control Unit.
Check all connections and wiring. Consult a
service agent.