Samsung AQV12A1ME Service Manual page 10

Hide thumbs Also See for AQV12A1ME:
Table of Contents

Advertisement

warm air.
*High temperature release function : The
outdoor unit for and compressor ON/OFF
c o n t rol for safety operation, when the over-
heat is heat exchanger of indoor unit.
*De-ice : Deicing operation is controlled by
indoor unit's heat exchanger temperature
and accumulating time of compre s s o r ' s
o p e r a t i o n .
De-ice end by sensing of the processing time
by de-ice Condition.
4. D RY MODE :
*Ac c o rding to the diff e rence between the set
t e m p e r a t u re (Ts) and indoor temperature
( Tr), the operation frequency of compre s s o r
as per area is contro l l e d .
(Cooling are a / C O M P
a rea/Monitoring are a )
Cooling area : same as the cool mode
o r
C O M P
ON/OFF area : repeatation of
C O M P
o r
f requency 36[Hz] for 4 minutes
o p e r a t i o n / 0 [ H z ] ( o ff) for 6 minutes
Monitoring area : COMP
5. TURBO MODE : This mode is available in
A U TO, COOL, HEAT, DRY, FAN MODE.
When this button is pressed at first, the air
conditioner is operated "powerful" state for
30 minutes re g a rdless of the set tempera-
t u re, room temperature .
When this button is pressed again, or when
the operating time is 30 minutes, turbo
operation mode is canceled and returned to
the previous mode.
*But, if you press the TURBO button in DRY
or FAN mode that is changed with A U TO
mode automatically.
6 . S L E E P MODE : Sleep mode is available
only in COOL or HEAT mode.
The operation will stop after 6 hours.
*In COOL mode : The setting temperature
is automatically raised by 1°C each 1hour
Samsung Electronics
o r
O N / O F F
o r
o ff .
Operating Instructions and Installation
When the temperature has been raised by
total of 2°C, that temperature is main-
t a i n e d .
*In HEAT mode : The setting temperature
is automatically droped by 1°C each 1hour.
When the temperature has been droped by
total of 2°C, that temperature is main-
t a i n e d .
7. FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending
on both the diff e rence between setting and
the room temperature .
8 . C O M P U L S O RY O P E R ATION :
For operating the air conditioner without
the remote contro l l e r.
* A U TO : The operating is the same func-
tion that A U TO MODE in the remote con-
t ro l l e r. And each time you press the button
the 5WAY function is changed as follow.
STD
N ATURE
SILENCE
POWER OFF
Each time you press This button, 5WAY
function is changed in the following order
S T D ( s t a n d a rd)
N ATURE
POWER(High-speed)
Saving)
S I L E N C E
S T D ( s t a n d a rd)(
N ATURE(
) : The unit is operated
POWER(
) : The unit is
S AVING(
) : The unit is operated in
SILENCE(
) : The unit is operated
Each mode has Auto, Cool and SLEEP o p e r-
ation designed in advarc e .
MC-Service
POWER
S AVING
S a v i n g ( P o w e r-
) : General operation
M o d e
a c c o rding to health
pattern contro l
operated in
powerful state
power saving state
q u i t e l y
3-3

Hide quick links:

Advertisement

Table of Contents
loading