Blower Data - Lennox SIGNATURE SLP99DFV Installation Instructions Manual

Table of Contents

Advertisement

BLOWER DATA

SLP99DF070XV36B BLOWER PERFORMANCE (less filter)
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
BLOWER DATA
SLP99DF090XV36C BLOWER PERFORMANCE (less filter)
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single-stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance Table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, and 38%, (DIP switch selectable) of the same second-stage COOL speed position minimum 250 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 250 cfm.
®
35%
40%
495
543
473
516
450
489
430
467
410
444
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
625
785
890
575
710
830
520
615
710
35%
40%
710
756
670
713
629
669
559
599
488
530
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
610
770
900
545
690
805
465
620
720
Page 45
Heating Input Range and Blower Volume - CFM
50%
60%
639
735
604
691
568
647
540
614
512
580
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
995
910
890
845
820
755
Heating Input Range and Blower Volume - CFM
50%
60%
848
940
799
885
749
829
681
763
614
697
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
1035
920
920
835
810
750
70%
80%
90%
830
926
1022
778
866
953
726
805
884
687
761
834
649
717
785
Medium-
Medium
Low
High
1075
1230
960
1125
885
985
70%
80%
90%
1033
1125
1217
971
1057
1143
910
990
1070
845
927
1009
781
865
948
Medium-
Medium
Low
High
1080
1215
1000
1135
890
1025
100%
1118
1041
963
908
853
High
(Default)
1365
1265
1150
100%
1309
1230
1150
1091
1032
High
(Default)
1385
1255
1145