Lennox SIGNATURE SLP99UHV Installation Instructions Manual page 45

Hide thumbs Also See for SIGNATURE SLP99UHV:
Table of Contents

Advertisement

BLOWER DATA
SLP99UH070XV36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
BLOWER DATA
SLP99UH090XV36C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between.
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28% and 38% (DIP switch selectable) of the same second-stage COOL speed position.
minimum 250 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 250 cfm.
®
35%
40%
489
538
450
496
410
453
380
419
349
385
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
600
740
840
555
665
770
500
600
680
35%
40%
687
734
654
697
621
660
581
616
540
572
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
625
710
830
565
670
760
520
610
685
Page 45
Heating Input Range and Blower Volume - CFM
50%
60%
636
735
588
680
539
624
498
578
458
531
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
970
860
855
810
790
705
Heating Input Range and Blower Volume - CFM
50%
60%
827
921
782
867
737
814
687
757
637
701
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
950
875
860
800
785
720
70%
80%
90%
833
931
1030
772
864
956
710
796
881
657
736
815
604
676
749
Medium-
Medium
Low
High
1060
1215
960
1130
840
1005
70%
80%
90%
1014
1108
1201
953
1038
1123
891
968
1045
828
899
970
766
830
895
Medium-
Medium
Low
High
1040
1210
945
1100
840
970
100%
1128
1048
967
895
822
High
(Default)
1365
1265
1140
100%
1295
1209
1122
1041
959
High
(Default)
1360
1240
1115

Advertisement