COMFORT SLEEP OPERATION
For comfortable sleep, automatically control air fl ow and automatically turn OFF
(Except in DRY mode).
1. Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
2. Press
to cancel the comfort sleep operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
HADA CARE FLOW OPERATION
12
HADA CARE FLOW
Air fl ow upward to the ceiling, provide Indirect air fl ow to body and homogenize
room temperture.
HADA CARE FLOW operation
Press
For start and stop HADA CARE FLOW
HADA CARE FLOW
Note:
● During HADA CARE FLOW mode, FIX and SWING button cannot active
POWER-SELECTION AND SILENT
13
OPERATION (OUTDOOR UNIT)
Power-Selection (
)
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%, 75%,
or 50% and can be implemented by POWER-SELECTION. The lower percentage,
the higher saving and also longer compressor lifetime.
Note:
● When the level is selected, POWER-SEL level fl ashes on remote LCD
display for 3 seconds.
In case of 75% and 50% level, number "75" or "50" also fl ashes for
2 seconds.
● Due to the reason that POWER-SELECTION function limits the
maximum current, inadequate cooling or heating capacity may occur.
Silent Operation (
)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will be
optimized to deliver such silent experience. The silent operation can be selected
from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to
ensure having suffi cient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity and
the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit's sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit by
4 dB(A).
Note:
● While activating of Silent operation, inadequate heating (or cooling)
capacity may occur.
Power-Selection and Silent Operation (Outdoor Unit)
[100%]
SILENT#2
Cancel
HADA CARE FLOW
[75%]
[50%]
SILENT#1
14
TIMER OPERATION
Set the timer when the air conditioner is operating.
Setting the ON Timer
1
Press
: Set the desired
ON timer.
2
Press
: Set the timer.
3
Press
: Cancel the timer.
Note:
● Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
● The setting will be saved for the next same operation.
15
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
The P mark displays.
3. Press
: Operate the preset operation.
16
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
for 3 seconds until brightness level (
or
) is shown on remote control LCD then release the button.
2. Press
or
Rise
Decrease
Remote control
Operation display
LCD
Lamp illuminates full brightness.
Lamp illuminates 50% brightness.
Lamp illuminates 50% brightness and the
operation lamp is turned off.
All lamps are turned off.
● In the examples of
and
, the lamp illuminates for 5 seconds before
going off.
17
AUTO RESTART FUNCTION SETTING
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
● Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
● Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note:
● In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
● Default setting of AUTO RESTART OPERATION is ON.
SELF CLEANING OPERATION (COOL
18
AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.
Setting the OFF Timer
Press
: Set the desired
OFF timer.
Press
: Set the timer.
Press
: Cancel the timer.
for 3 seconds to memorize the setting.
,
to adjust brightness in 4 levels.
Brightness
100%
50%
50%
All turned off