Troubleshooting - Saturn SHP4-HD Owner's Manual

24" heavy duty gas hotplate
Table of Contents

Advertisement

TROUBLESHOOTING

SYMPTOM
Burners won't light
Front or rear burner
won't light
Pilot will not light
Burner not hot enough
POSSIBLE CAUSE
Gas supply off
Air in lines
Pilot valve not lit
Control not on
Water in burner
Damaged temperature control,
Burner or other internal
component
Gas supply off
Air in lines
Pilot valve not on
Temperature control not set
Shutter or nozzle out of
adjustment
Damaged temperature control,
burner or other internal
component
Page 13
SUGGESTED REMEDY
Check main / unit gas valves
Turn gas valve on. Attempt to
light pilot every 15 sec.
Turn off gas - allow unit to
vent for 5 minutes. Turn gas
back on and light pilot
Turn temperature control to ON
Set to desired setting when lit
Remove burner and dry
thoroughly
Contact manufacturer for repairs
Check main / unit gas valves
Turn pilot valve on. Attempt to
light pilot every 15 sec.
Turn pilot valve on / adjust
Adjust for desired temperature
Contact qualified technician for
adjustment
Contact manufacturer for repairs
NOTE: There are no user
serviceable components in the
burner assemblies or in the control
valves. In all cases of damage
or malfunction,
contact your manufacturer for
repairs.

Advertisement