Thermo Pride OH8FA119D60C Installation And Operation Manual page 38

Oil fired furnace
Table of Contents

Advertisement

For PSC systems, the ½ hp motor is equipped with 4 speeds. The unit is set for mid-fire temp rise @
66ºF. See table for proper blower motor set up:
OH6FA072D48
ALTERATIONS REQ'D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
COOLING UNIT
24,000
30,000
36,000
42,000
48,000
Speed Tap\ Static
Pressure
Low
ML
MH
High
Low
ML
MH
High
Speed Tap\ Static
Pressure
Low
ML
MH
High
Speed Tap\ Static
Pressure
Low
ML
MH
High
Speed Tap\ Static
Pressure
Low
ML
MH
High
HTG Speed by Input
Low
Fire
Low
Low
Low
Low
Low
Furnace Airflow (CFM) vs. External Static pressure (in. WC.)
0.1
0.2
0.3
930
915
912
1155
1152
1130
1442
1432
1418
1802
1762
1705
Furnace Motor Current Draw (Amps) vs. External Static pressure (in. WC.)
3.3
3.1
3.0
4.2
4.0
3.9
5.4
5.2
5.0
6.6
6.4
6.0
High Fire Temperature Rise vs. External Static pressure (in. WC.)
0.1
0.2
0.3
90
91
91
72
72
74
58
58
59
46
47
49
Mid Fire Temperature Rise vs. External Static pressure (in. WC.)
0.1
0.2
0.3
72
73
73
58
58
59
46
47
47
37
38
39
Low Fire Temperature Rise vs. External Static pressure (in. WC.)
0.1
0.2
0.3
60
61
61
48
48
49
39
39
39
31
32
33
Figure 19A: Heating speed by input
Recommended CLG Speed
Mid
High
Fire
Fire
ML
MH
ML
MH
ML
MH
ML
MH
ML
MH
0.4
0.5
910
822
1126
1085
1382
1334
1635
1569
2.9
2.6
3.7
3.6
4.7
4.4
5.7
5.5
0.4
0.5
92
101
74
77
60
62
51
53
0.4
0.5
73
81
59
61
48
50
41
42
0.4
0.5
61
68
49
51
40
42
34
35
33
Low
Med Low
Med High
Med High
High
0.6
0.7
774
730
1042
920
1293
1230
1493
1428
2.5
2.4
3.3
3.0
4.2
4.0
5.2
5.0
0.6
0.7
108
114
80
91
64
68
56
58
0.6
0.7
86
91
64
72
52
54
45
47
0.6
0.7
72
76
53
60
43
45
37
39