Thermo Pride OH8FA119D60C Installation And Operation Manual page 35

Oil fired furnace
Table of Contents

Advertisement

Heating Speed Set-ups ( 2 – Stage )
OH6FX072DV4
FAN
CONTROL
SW 1
SWITCH
SETTINGS
3 – OFF
2 – OFF
1 – OFF
3 – OFF
2 – OFF
1 – ON
3 – OFF
2 – ON
1 – OFF
3 – OFF
2 – ON
1 – ON
3 – ON
2 – OFF
1 – OFF
3 – ON
2 – OFF
1 – ON
FACTORY
3 – ON
SW1
2 – ON
SWITCH
SETTINGS
1 – OFF
3 – ON
2 – ON
1 – ON
HEATING AIR FLOW / TEMPERATURE RISE
LOW CAPACITY
LOW FIRE
BTUH
60,000
APPROX.
HEATING
CFM/RISE
CFM
(ºF)
740
592 / 94º
812
650 / 85º
883
706 / 79º
968
744 / 72º
1054
843 / 66º
1153
922 / 60º
1267
1013 / 55º
1424
1139 / 49º
= Recommended heating speed setting
Figure 18-2: ECM 2-stage blower motor speed chart
30
HIGH CAPACITY
HI FIRE
LOW FIRE
72,000
72,000
APPROX.
APPROX.
CFM/RISE
CFM/RISE
(ºF)
(ºF)
740 / 90º
592 / 113º
812 / 82º
650 / 103º
883 / 75º
706 / 94º
968 / 69º
774 / 86º
1054 / 63º
843 / 79º
1153 / 58º
922 / 72º
1267 / 53º
1013 / 66º
1424 / 47º
1139 / 59º
HI FIRE
90,000
APPROX.
CFM/RISE
(ºF)
740 / 113º
812 / 103º
883 / 94º
968 / 86º
1054 / 79º
1153 / 72º
1267 / 66º
1424 / 59º

Hide quick links: