CONSUMER: READ AND SAVE THESE INSTRUCTIONS
DANGER
Be sure to comply with the instructions and warnings provided with this heater. Failure to
comply can result in fire or explosion that can cause property loss, bodily injury, or loss
of life. Only persons who can follow and understand these instructions should operate or
service this heater. If you need heater info; such as an operating manual, labels, etcetera,
contact Pinnacle Climate Technologies at 866-676-1989.
DANGER
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS
OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an
unvented portable heater that uses air (Oxygen) from within the area in which it is used.
Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 5.
WARNING
instructions. Never use the heater in spaces which contain products such as; gasoline,
solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown
chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which
it is used. Adequate combustion and ventilation air must be provided. Refer to "Ventilation"
on page 5. Bulk fuel storage should be a minimum of 25 feet from heater.
WARNING
Failure to comply with the precautions and instructions provided with this heater can result
in death, serious bodily injury, property loss or damage from the hazards of fire, soot pro-
duction, explosions, burns, asphyxiation or carbon monoxide poisoning. Only persons who
can read and understand these instructions should use or service this heater
U.S. Patent No. 9,644,863
FACTORY ID: 001
Model Numbers
REM-150T-SDR-O / REM-220T-SDR-O
Safety Information
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep
combustibles such as; building materials, paper or cardboard a
safe distance away from the heater as recommended by these
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ
AND THOROUGHLY UNDERSTAND THESE SAFETY AND
OPERATING INSTRUCTIONS.
Fax: 320-251-2922 • Web:
Silent Drive
FORCED AIR HEATER
®
User's Manual &
Operating Instructions
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
www.remingtonheater.com
© 2018 Pinnacle Climate Technologies, Inc.
.
(866) 676-1989
• Email: info@pinnacleclimate.com
RGSA-403

Advertisement

Table of Contents
loading

Summary of Contents for Remington Silent Drive REM-150T-SDR-O

  • Page 1 Silent Drive FORCED AIR HEATER ® User’s Manual & Operating Instructions Model Numbers REM-150T-SDR-O / REM-220T-SDR-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS Safety Information GENERAL HAZARD WARNING: READ AND UNDERSTAND DANGER ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater.
  • Page 2 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE DO NOT START THE HEATER WHEN EXCESS OIL HAS WARNING ACCUMULATED. WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT. This product can expose you to chemicals, including lead, which WARNING are known to the State of California to cause cancer and birth defects or other reproductive harm.
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Safety Information NEVER use duct work in front or rear of heater. RISK OF WARNING ELECTRIC NEVER move or handle heater while still hot. SHOCK! NEVER transport heater with fuel in tank. ALWAYS use only the electrical power (voltage and NEVER use with an external fuel tank.
  • Page 4: Wiring Diagram

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE DFV Wiring Diagram Wiring Diagram 1. Igniter 2. Pump 3. Motor 4. Condensor 5. Limit Control 6. Dump 7. PCB Assembly 8. Thermistor 9. Photocell 10. P-Solenoid 11.
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE What’s In The Box: REM-150T-SDR-O / REM-220T-SDR-O Tools Needed: Tip: Be sure to remove the axle from the - Phillips Head Screw Driver side of the Styrofoam packaging. - 8 mm open end wrench Tip: Use a power screwdriver and - 19 mm open end wrench...
  • Page 6: Operation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation Ventilation: TIP: If the heater does not ignite, the thermostat may be set too low. Increase - Risk of indoor air pollution and Carbon the temperature to a higher setting until the Monoxide Poisoning.
  • Page 7: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Long Term Storage: Service: 1. Drain fuel through the drain plug in the bottom of DO NOT TAMPER WITH THE UNIT. HAVE the fuel tank. A COMPETENT SERVICEMAN MAKE ANY 2.
  • Page 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Service (Continued): PHOTOCELL: The photocell should be cleaned using a cotton FUEL FILTER: swab dipped in alcohol or water at least once The fuel filter should be cleaned at least twice per heating season, or more depending on per heating season.
  • Page 9: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Troubleshooting Guide Problem Possible Cause Solution Heater Ignites, but main PCB shuts 1. Dirty fuel filter. 1. Clean / replace fuel filter. off after a short period of time. 2.
  • Page 10: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 35 36 Parts List Item # Description REM-150T-SDR-O REM-220T-SDR-O Upper Shell 70-001-5010 70-001-5010 Combustion Chamber 70-011-1000 70-011-1010 Main Power PCB 70-027-2305 70-027-2305 Power PCB Case 70-027-1250 70-027-1250 PCB Lead Wire...
  • Page 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List Item # Description REM-150T-SDR- REM-220T-SDR- Limit Control Bracket 70-019-1010 70-019-1010 Photocell 70-016-1000 70-016-1000 Photocell bracket 70-016-1020 70-016-1020 Air Draft Tube 70-300-0001 70-300-0001 Duct Bracket 70-300-0020 70-300-0020 Sirroco Fan 70-060-0001...
  • Page 12: Limited Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater If Pinnacle Climate Technologies, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Page 13: Información De Seguridad

    CALENTADOR DE AIRE FORZADO SilentDrive ® Manual del usuario e Instrucciones de operación Modelos N.° REM-150T-SDR-O / REM-220T-SDR-O CONSUMIDOR: LEA Y CONSERVE ESTAS INSTRUCCIONES Información de seguridad ADVERTENCIA GENERAL DE PELIGRO: LEA Y COMPRENDA TODAS LAS INSTRUCCIONES EN ESTE MANUAL ANTES DE ARMAR, ENCENDER O DAR SERVICIO AL CALENTADOR.
  • Page 14 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO SE HAYA ACUMULADO UN EXCESO DE ACEITE. ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO LA CÁMARA ESTÁ CALIENTE. Este producto puede exponerlo a sustancias químicas, incluyendo ADVERTENCIA plomo, conocidas en el estado de California como causantes de cáncer...
  • Page 15: Especificaciones

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Información de seguridad ¡RIESGO DE ADVERTENCIA NUNCA use conductos en la parte frontal o posterior del calentador. DESCARGA NUNCA mueva ni manipule el calentador mientras esté caliente. ELÉCTRICA! NUNCA transporte el calentador con combustible en el tanque.
  • Page 16: Diagramas Eléctricos

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN DFV Wiring Diagram Diagramas eléctricos 1. Encendedor 2. Bomba 3. Motor 4. Condensador 5. Control de limite 6. Desconexión fuente alim. 7. Conjunto PCI 8.
  • Page 17 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Qué hay en la caja: REM-150T-SDR-O / REM-220T-SDR-O Herramientas necesarias: Consejo: Asegúrese de retirar el eje del lateral del empaque de espuma de poliestireno. - Destornillador Phillips - Llave plana de 8 mm Consejo: Use un destornillador eléctrico y una llave de...
  • Page 18 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Funcionamiento Ventilación: CONSEJO: Si el calentador no se enciende, el SDR 220 Rating Label + Control Panel termostato podría estar ajustado demasiado bajo. - Riesgo de contaminación del aire interior y de envenenamiento Suba la temperatura a un valor superior hasta que el por monóxido de carbono.
  • Page 19: Mantenimiento

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Almacenamiento a largo plazo: Servicio: 1. Drene el combustible quitando el tapón de drenaje que NO ALTERE LA UNIDAD. PIDA A UN TÉCNICO está...
  • Page 20 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Servicio (Continuación): FOTOCÉLULA: La fotocélula debe limpiarse con hisopo de algodón remojado FILTRO DE COMBUSTIBLE: en agua o alcohol al menos una vez por cada temporada de El filtro de combustible debe limpiarse al menos dos veces por calefacción o más según las condiciones en que esté.
  • Page 21: Guía Para La Solución De Problemas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Guía para la solución de problemas Problema Posible causa Solución El calentador se enciende, pero la placa Filtro de combustible sucio. Limpie o reemplace el filtro de de circuitos impresos principal se apaga combustible.
  • Page 22: Vista Detallada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Vista detallada 35 36 Lista de piezas Pieza # Descripción REM-150T-SDR-O REM-220T-SDR-O Coraza superior 70-001-5010 70-001-5010 Cámara de combustión 70-011-1000 70-011-1010 Placa de circuitos impresos (PCI) principal 70-027-2305 70-027-2305 Caja de la placa de circuitos impresos...
  • Page 23 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Lista de piezas Pieza # Descripción REM-150T-SDR-O REM-220T-SDR-O Soporte del control de limite 70-019-1010 70-019-1010 Fotocélula 70-016-1000 70-016-1000 Soporte de la fotocélula 70-016-1020 70-016-1020 Tubo de Caudal de Aire 70-300-0001...
  • Page 24: Garantía Limitada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este calentador Si Pinnacle Climate Technologies, Inc. descubre que el artículo únicamente al comprador minorista original, como libre de está...

This manual is also suitable for:

Silent drive rem-220t-sdr-o

Table of Contents