SPZ--8000 Digital Integrated Flight Control System
Control or
Sensor
Mode
FLC
DADC
ALT
DADC and ALT
Pre--
Pre
control
control
select
select
VALT hold
FMS
VALT Pre--
FMS
select
select
System Performance and Operating Limits
System Limits
7-10
Parameter
MACH engage range
MACH hold error
Pitch limit
Pitch rate limit
IAS engage range
IAS hold engage error
Preselect capture
Maximum vertical speed
Maximum vertical speed
for capture
Capture maneuver
Capture maneuver
damping
Pitch limit
Pitch rate limit at
capture
Maximum altitude
Maximum altitude
capture error
ALT hold engage range
ALT hold engage error
Pitch limit
Pitch rate limit
Preselect capture range
Maximum vertical speed
for capture
Capture maneuver
damping
Pitch limit
Pitch rate limit at
capture
M i
Maximum altitude
Maximum altitude
ltit d
capture error
capture error
Table 7--1 (cont)
Value
0.4 to 0.9 Mach
0.01 Mach
20_
.3g maximum
80 to 400 kts
5 kts
0 to 60,000 feet
12,000 feet/minute
12,000 feet/minute
Complemented vertical
Complemented vertical
acceleration
20_
.3g maximum
25 feet
25 feet
0 to 60,000 feet
40 feet
20_
.3g maximum
0 to 60,000 feet
12,000 feet/minute
Complemented vertical
acceleration
20_
.3g maximum
25 f
25 feet
25 feet
t
A28--1146--055
REV 2

Hide quick links:

Advertisement

Table of Contents
loading