24) Remove the front insulation panel, then remove splash guard, cube guide B and cube
guide A. Remove the overflow cap, overflow pipe, water shield, and drain plug. After the
water tank has drained, replace the drain plug, water shield, overflow pipe, overflow cap,
cube guide A, cube guide B, splash guard, and front insulation panel.
Sanitizing Rinse 3
25) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position.
26) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
27) Remove the front insulation panel, then remove splash guard, cube guide B and cube
guide A. Remove the overflow cap, overflow pipe, water shield, and drain plug. After the
water tank has drained, replace the drain plug, water shield, overflow pipe, overflow cap,
cube guide A, cube guide B, splash guard, and front insulation panel.
28) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
29) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position. Note: If on a dispenser unit, turn on the dispenser unit
power supply.
30) Replace all panels in their correct positions.