Maintenance And Service; Maintenance And Cleaning; Inserting/Changing The Button Cell (See Figure D); After-Sales Service And Application Service - Bosch Professional D-tect 200 C Original Instructions Manual

Wallscanner
Hide thumbs Also See for Professional D-tect 200 C:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
54 | English
If the info/help symbol is shown on the display above the right-hand function button (6),
you can access context-related information and help by pressing the right-hand function
button (available when changing wall type and view, as well as in all measuring modes of
the <Object Detection> and in the <Leakage Detection>).

Maintenance and Service

Maintenance and Cleaning

Check the measuring tool before each use. If the measuring tool is visibly damaged
u
or parts have become loose inside the measuring tool, safe function can no longer be
ensured.
Always keep the measuring tool clean and dry to ensure optimum, safe operation.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a dry, soft cloth. Do not use any detergents or solvents.
Only store and transport the measuring tool in the protective bag (21) or the case (24).
If the measuring tool needs to be repaired, send it off in the protective bag (21) or the
case (24).
If the wheels (2) are worn, they must be replaced. The wheels are available in the spare
parts range of Bosch.
Inserting/changing the button cell (see figure D)
To be able to save the time on the measuring tool, a button cell (32) must be used.
Unscrew the screw (30) on the button cell holder (29). Pull the button cell holder out of
the button cell port (31) with an auxiliary tool (e.g. a flat-head screwdriver).
Remove the empty button cell (32) and insert a new button cell. Ensure that the polarity
is correct according to the illustration on the button cell holder (the positive terminal of
the button cell must be facing upwards).
With the button cell fitted, slide the button cell holder (29) into the port (31). Ensure
that the button cell holder is inserted correctly and fully, as otherwise protection from
dust and splashes is no longer guaranteed.
Retighten the screw (30) on the button cell holder (29).

After-Sales Service and Application Service

Our after-sales service responds to your questions concerning maintenance and repair of
your product as well as spare parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
1 609 92A 5L5 | (11.01.2021)