Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this
equipment. The exclamation point symbol alerts you to a general warning and the hazard
symbols refer to procedure-specific risks. When these symbols appear in the body of this
manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols
and warnings not covered in this section may appear throughout the body of this manual where
applicable.
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric
current. This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
Improper installation of the grounding plug is able to result in a risk of electric shock.
When repair or replacement of the cord or plug is required, do not connect the grounding
wire to either flat blade terminal.
The wire with insulation having an outer surface that is green with or without yellow stripes
is the grounding wire.
Check with a qualified electrician or serviceman when the grounding instructions are not
completely understood, or when in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed
by a qualified electrician.
This product is for use on a nominal 120V or 230V circuit and has a grounding plug similar
to the plugs illustrated below.
Only connect the product to an outlet having the same configuration as the plug.
Do not use an adapter with this product.
Extension Cords:
Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle that
accepts the plug on the product.
Make sure your extension cord is not damaged. If an extension cord is necessary use 12
AWG (2.5mm
An undersized cord results in a drop in line voltage and loss of power and overheating.
AWG (American Wire Gauge)
4
2
) minimum to carry the current that the product draws.
Conductor Size
Metric
16
1.5 mm
12
2.5 mm
Length
Maximum
2
25 ft. (8 m)
2
50 ft. (15 m)
ti24583b
3A4416A