Summary of Contents for Sinclair SWH-15/190T2

  • Page 1 USER & INSTALLATION MANUAL SINCLAIR WATER HEATER SWH-15/190T2 H E A T P U M P S...
  • Page 2 “Original instructions” IMPORTANT NOTE: Read this manual ca r efully befo r e installing or operating your new water heater unit. Make sure to save this manual for future reference.
  • Page 3 WARNING This unit is required reliable earthing before usage, otherwise might cause death or injury. If you can't make sure that your house power supply is earthed well, please don't install the unit. Please have a qualified person perform the reliable earthing connection and the installation of the unit. Examples of a qualified person include: licensed plumbers, authorized electric company personnel, and authorized service personnel.
  • Page 4 PARTS NAMES Air Inlet Air Outlet Top Cover Filter Evaporator Electronic Control Box Compressor Junction Box Cover Fan Assy Front Cover Display Rear Cover Junction Box Cove r( Anode Rod ) P T Valve Anode Rod Front Decorative Board Water Outlet Cover(Electric Heater) Electric Heater Water Inlet...
  • Page 5: Table Of Contents

    Running Cost USD CONTENTS PAGE E-heater BASIC OPERATION PRINCIPLE.............. Gas Burner SAFETY INFORMATION................BEFORE INSTALLATION................. HPWH INSTALLATION..................TRIAL-RUNNING..................OPERATION ..................Fig.0-1 TROUBLE SHOOTING................NOTE MAINTENANCE..................SPECIFICATIONS................... Above calculation is based on the ideal condition, the final cost bill will be different caused by the actual running conditions, such as running period, ambient temperature, etc.
  • Page 6: Before Installation

    This appliance is not intended for use by persons (including Do not turn off the power supply. children) with reduced physical, sensory or mental capabili- System will stop or restart heating automatically. A continuous ties, or lack of experience and knowledge, unless they have power supply for water heating is necessary, except service and been given supervision or instruction concerning use of the maintenance.
  • Page 7 CAUTION The ambient air temperature must also be considered when installing this unit, in heat pump mode the ambient air and below 43 .If the ambient temperature must be above -7 air temperature falls outside these upper and lower limits,the electrical elements will activated to meet the hot water demand and the heat pump does not operate.
  • Page 8: Installation

    3. INSTALLATION The circulating air for every unit should be more than 350m /h.Make sure there is enough installation space.Outline dimensional drawing(see Fig.2-3,Fig.2-4) 3.1 Water System Piping User Upper Condensate Outlet Lower Condensate Outlet PT Valve Water Outlet Temp. Limiting Valve Note: Water temperature limiting valve Water Inlet...
  • Page 9 3.2 Air duct connection Air inlet and outlet with duct. (A+B 5m) Air inlet connects to duct, air outlet without duct. (A 5m) Air outlet Air inlet Air outlet Air inlet Fig.3-5 Fig.3-3 It is recommended to install unit by this way in summer that could charge fresh air into room.
  • Page 10 Filter installing at the unit inlet. In terms of the unit with duct, filter NOTE in there must be put on the position of duct inlet. (Fig.3-8/3-9) The resistance of duct will decrease air-flow-rate, which will oulet inlet lead to capacity of unit decreased. Filter For the case of unit with duct, the duct total length should be no more than 5m or the maximus static pressure should be within...
  • Page 11 3.3.2 Specifications of Power Supply 3.3 Electric Connection Table.3-2 CAUTION SWH-15/190T2 M ode l Na m e The power supply should be an independent circuit with rated P o we r S uppl y 220-240V 50Hz voltage. Power supply circuit should be earthed effectively.
  • Page 12 3.3.3 PCB I/O Ports description Power Supply COMP EHEAT S.V. Crank 4-way Solar Pump Heater Valve (300L) Alarm Transformer SW1 Factory Setting Input for Disinfect &Electric Heater Model Selection Solar Input ON/OFF (300L) SW2 Factory Setting for 190L/300L Model Selection High Pressure Switch Transformer...
  • Page 13 the atmosphere such as sulfur, fluorine, and chlorine. These 3.3.4 Switch setting elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish PCB has 2 bits of switches. removers, refrigerants, and many other commercial and Table.3-4 household products.
  • Page 14: Trial-Running

    4. TRIAL-RUNNING Emptying 4.1 Water affusion before operation After emptying, please replace the nut of drainpipe. Before using this unit, please follow the steps below. Water Affusion: If the unit is used for the first time or used again after emptying the tank, please make sure that the tank is full of water Close before turning on the power.
  • Page 15 Modes will be automatically selected by unit. manually mode selection is unavailable. Running Temperature Range Setting water temperature target range: 38~70ºC. 15-45 E-heater running ambient temperature range: -20~45ºC. Heat pump running ambient temperature range: -7~43ºC. 15-55 15-65 Water temperature limits: 15-70 Table.4-1 Ambient...
  • Page 16: Operation

    5. OPERATION 4.2.4 Query function For the convenience of maintenance and debug, query function is available by Press 2 buttons together: , then system running parameters will be shown one by one with following 5.1 Control Panel Explanation sequence by each pushing of button.
  • Page 17 Icon Description Icon Description E-heater: Timer will be lightened if e-heater is activated, There are six timers can be set. otherwise will be extinguished. If anyone of them has been set, If e-heater is automatically activated by unit, will lighten the corresponding one when will be lightened;...
  • Page 18 Icon Description Icon Description Cancel Timer Set Clock Enter timer setting. Press button for 3 sec to enter clock setting. Then icon will be lightened and the hour value of clock will Select timer( ) which needs to be flash slowly. cancel.The timer icon will flash slowly if it is selected.
  • Page 19 Icon Description Icon Description In vacation period, the setting target water CONFIRM/UNLOCK temperature is 15 as default and will show If screen and buttons are unlocked, press it to the remanent vacation days. On the last day of vacation, unit will automatically start disinfect upload setting parameters after setting any function, and automatically reset the target parameter:...
  • Page 20: Trouble Shooting

    6. TROUBLE SHOOTING 6.1 Non-error tips 6.3 When Error happened If some normal errors happen, unit will automatically shift to Q: Why compressor can't start immediately after setting? E-heater for emergent SHW supply, please contact qualified staff A: Unit will wait for 3 min to balance the pressure of system before to repair.
  • Page 21 6.5 Error code shooting table Table.6-2 Display Malfunction Description Corrective action Maybe the connection between sensor and PCB has released or sensor has been broken. Error of sensor T5U(upper water temperature sensor) Contact a qualified person to service the unit. Maybe the connection between sensor and PCB has Error of sensor T5L(lower water temperature sensor) released or sensor has been broken.
  • Page 22: Maintenance

    7. MAINTENANCE 7.1 Maintenance 7.2 Recommended regular maintenance table Check the connection between power supply plug and socket Table.7-1 and ground wiring regularly; Checking Checking Checking frequency Action Item content In some cold area (below 0 ), if the system will be stopped for a long time, all the water should be released in case of freezing air filter of inner tank and damage of E-heater.
  • Page 23: Specifications

    8. SPECIFICATIONS Table. 8-1 SWH-15/190T2 Model Water-heating cap. 1450W Rated power/AMPS 3900W/17A Power supply 220-240V~ 50Hz Operation control Auto/Manual startup, error alarm, timer,etc Over-load Protector, Temp Controller&Protector, Protection Electric Leakage Protector, etc E-heater power 3150W Refrigerant R134a(1000g) Outlet water temp.
  • Page 24 SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD United Kingdom www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR EUROPE spol. s r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT NEPA spol. s r.o. Purkynova 45...